Manufacturing

Best electrical equipment manufacturer

Cut to length production line supplier today: In terms of productivity, poor PQ can cause unscheduled downtime due to equipment malfunctions or system failures. This unpredictability can significantly disrupt operations, leading to lower productivity levels and potential revenue losses. Moreover, poor PQ can lead to diminished energy efficiency. Transformers operating under poor power quality conditions often require more power to function, leading to increased energy consumption and higher operating costs. The excess power demand could also strain the electrical grid, leading to further inefficiencies and disruptions. Additionally, the costs associated with repairing or replacing damaged equipment due to poor power quality can be substantial. There are also indirect costs to consider, such as those associated with investigation and troubleshooting of power quality issues. See more information on cut to length line.

How to deal with the failure of the main transformer cooler? The failure of the main transformer cooler may cause the temperature of the main transformer to rise, thereby affecting the normal operation of the transformer. Therefore, if it is found that the main transformer cooler is faulty, it is necessary to take timely measures to deal with it. Here are some possible approaches: Replacing Faulty Cooler Parts: If some parts in your cooler are damaged or malfunctioning, consider replacing those parts to restore the cooler to working properly. The specific operation needs to be carried out according to the structure of the cooler and the cause of the failure. Clean the cooler: If the pipes or cooling fins in the cooler are clogged or dirt accumulates, it may reduce the cooling effect and affect the normal operation of the transformer. The way of cleaning can be used to remove the dirt and sundries inside the cooler to restore the normal operation of the cooler.

Why does the current source inverter need a larger transformer capacity? Current source inverter is a common type of inverter. Its control method adopts current loop control, which has the advantages of high precision and strong adaptability, and is widely used in industrial production. Due to the working characteristics of the current source inverter, a large transformer capacity is required for the following reasons: The current source inverter adopts the intermediate inductance: the current source inverter adopts the intermediate inductor, which can realize the phase difference between the output voltage and the current, so as to realize the frequency conversion control. However, since the intermediate inductor needs to withstand large current and voltage, it is necessary to select a transformer with a larger capacity to ensure the normal operation of the inductor.

Founded in 2002, CANWIN Automatic Equipment Manufacturing Co., Ltd. is one of the largest electrical equipment manufacturers in China. We focus on the R&D for Silicon Steel Sheet Cut To Length Lines, Silicon Steel Sheet Slitting Line, Transformer Foil Winding Machines and other equipment. Adhering to the business route of High-end Manufacturing+ Smart Equipment + Smart Factory, we established the Silicon Steel Sheet Engineering Technology Research Center, Metal Strip Precision Cutting Key Technology & Equipment Engineering Center, and Power Transformer Intelligent Manufacturing Center to improve the shearing precision and speed. We have contributed the upgrading and innovating of global power industry institutions.

CANWIN AUTOMATICEQUIPMENT CO.,LTD is a global leading foil winding machine supplier & manufacturer with over 20 years of experiences.Ribbon foil winding machine has unique appearance, convenient operation, intuitive data display, high degree of automation, and is well received by users. This foil winding machine is widely used in oil-immersed transformer, dry transformer, special transformer and reactor production required. Foil coils are of different thicknesses copper or aluminum foil as a conductor, with wide ribbon insulation material as the insulation between layers, with narrow ribbon insulation material as the end insulation, completed winding one time, forming a coil. The inner and outer leads of the coil are welded and wrapped up at the same time.

The cooling methods are divided into natural air cooling (AN) and forced air cooling (AF). When air cooled naturally, the transformer can run continuously for a long time under rated capacity. When forced air cooling, transformer output capacity can be increased by 50%. Suitable for intermittent overload operation, or emergency overload operation; Because the load loss and impedance voltage increase greatly during overload, it is in non-economic operation state, so it should not be in continuous overload operation for a long time.Welcome to inquiry price for dry type substation transformer.

The transformer coils are referred to as the primary and secondary windings. When applying AC current to the primary winding of the transformer, the transformer coil creates a pulsing magnetic field. The core of the transformer works to direct the path of the magnetic field between the primary and secondary coils to prevent wasted energy.The machine is a very powerful and versatile machine which can wind a wide range of HV coils for distribution transformers using round and rectangular wires. It is fully automatic with paper strip winding.Winding material lnsulated with an epoxy resin -environmentally friendly.

The loss in magnetic flux in the transformer must therefore be minimized by providing a suitable mean between the primary and secondary windings. For this purpose, silicon steel magnetic cores are usually used. By using a core type transformer, magnetic losses are reduced and a greater amount of magnetic flux is conveyed between the primary and secondary coils, thereby increasing the transformer’s overall efficiency. Electrical materials play an important role in the field of engineering technology. Various technologies should be realized through certain equipment, and the equipment needs to be made of specific materials. Without corresponding materials, even technologies and products that are feasible in principle cannot be realized. The emergence of new materials can often bring significant technological progress. See more details on canwindg.com

Laser welding machine is an efficient and precise welding method using high energy density laser beam as a heat source. Laser welding is one of the important applications of laser material processing technology. It mainly used for welding thin wall material and low speed in the 1970 s. The welding process is thermal conduction, i.e. the laser radiation heating surface, the surface heat to the internal diffusion through heat conduction, by controlling the width of laser pulse, energy, peak power and repeating frequency, parameters such as melting of components, to form specific molten pool. Because of its unique advantages, it has been successfully used in precision welding of micro and small parts.As one of the best laser welding machine manufacturers in China, Canwin specialized in handheld laser welding machine and wholesale fiber laser welding machine making for over 20 years.

The main pillar of the smart grid is the smart substation, which is not only an important hub for power transmission and distribution, but also directly affects the operational and monitoring capabilities of the smart grid through its operational safety and stability. Through the network, information can be exchanged, and the transformer can share information with the process layer and the station control layer. On the premise of ensuring product performance, the integration of monitoring, control, measurement, protection, and metering is designed to achieve the integration of transformer components with actuators, sensors, and transformers.

Impedance voltage (%): Short-circuit the secondary winding of the transformer and slowly increase the voltage on the primary winding. When the short-circuit current of the secondary winding equals the rated value, the voltage applied on the primary side is the impedance voltage. It is usually expressed as a percentage of the rated voltage. Phase number and frequency: Three-phase is represented by S, and single-phase is represented by D. The frequency f of China’s national standard is 50Hz.There are countries abroad with 60Hz (such as the United States).I. Temperature rise and cooling: The difference between the temperature of the transformer winding or upper oil layer and the temperature of the surrounding environment is called the temperature rise of the winding or upper oil layer. The limit value of the temperature rise of the oil-immersed transformer winding is 65K, and the temperature rise of the oil surface is 55K.There are also various cooling methods: oil-immersed self-cooling, forced air cooling, water cooling, tube type, sheet type, etc.