Technology

Excellent hmi touch screen panel factory

Excellent hmi touch screen panel factory: Inherent human weaknesses: people have inherent weaknesses such as forgetfulness, error-prone, inattentiveness and emotional instability. A well-designed human-machine interface should minimize the amount of user memory when operating and using, and should strive to avoid possible errors; The user’s knowledge and education: the user’s education level determines his knowledge and experience of the computer system. China is the world’s largest market in terms of HMI demand, but it is not the world’s highest market in terms of HMI product sales, which means that low-end HMI users occupy a large share in China. The rapid development of national brands in recent years, taking low prices and other strategies, is attacking the low-end market in a big way, and has occupied a dominant position in the low-end market in China, winning the recognition of the majority of users. International brands are also gradually developing their economic products to capture the share of the low-end market. As a result, the overall performance of domestic HMI manufacturers has shown rapid growth due to their steady presence in the low-end market. Find extra details at https://www.mochuan-drives.com/products-56168.

Corresponding Functional Requirements: Gemerally, small plc have functions such as logic operation, timing and counting, which can be met for equipment that only needs to be controlled by switching quantity. For systems with switching control as the main and a small number of analog control, an enhanced plc with A/D and D/A conversion units and functions of addition and subtraction arithmetic operations and data transmission can be selected. For complex control, it is required to realized PID calculation, closed-loop control, communication networking and other functions, visual control scale and complexity, and choose mid-range or high-grade plc. However, medium and large PLC are more expensive and are generally used in large-scale process control and distributed control system.

Consistency principle: Including the consistency of color, operation area consistency, text consistency. That is, on the one hand, the interface color, shape and font are consistent with national, international or industry common standards. On the other hand, the interface color, shape and font are self-contained, and the color of different devices and their same design state should be consistent. Consistency in the aesthetic design of the interface details makes the operator feel comfortable when looking at the interface, so as not to distract his attention. Consistency also reduces errors for new operators, or for operators dealing with problems in emergency situations.

MochuanDrives supports industrial hmi touch panel from 4.3inch to 32inch, and supports multiple serial ports with different communication parameters to meet the needs of different projects. Provide free software and online technical one-on-one worry-free after-sales technical support. Through the setting of early warning programming, can monitor in advance whether there is a failure of the equipment in the electrical room, can effectively prevent the loss of sudden damage to equipment. Discover more details at mochuan-drives.com.

Industry-sepcific human machine interface may have specific definitions and classifications, such as industrial human machine interface(HMI or simply industrial HMI). Human-Computer Interaction: Human-Computer Interaction, Human-Computer Interaction (HCI, abbreviated HCI, also known as user interface or user interface): is a study of the interaction between a system and its users. Systems can be a variety of machines, or computerized systems and software. The human-computer interaction interface is usually the part that is visible to the user. The user communicates with the system and operates it through the HCI interface. This can be as small as the play button on a radio, or as large as the instrument panel on an airplane, or the control room in a power plant.

Supporting customized special technical parameters, special application scenarios or special process, special function realization, special performance, special application including shape, color etc. With NO MOQ before mass production. And will not accept to quantity production before customer 100% confirmation its stable quality to run in the device or equipment. Becuase quality is the soul of an enterprise. MochuanDrives customized pmsm motor mainly focuses on high-tech , high-end development, design, production, sales.

How To Solve Communication Failure Between HMI Operator Interface And PLC? When communication fails, some customers guess that it may be a problem with the touch screen all-in-one machine or the interface. Online simulation is to bypass the touch screen, use the PLC to connect directly to the computer, use our configuration software, connect the PLC’s own communication cable to the computer, conduct online simulation and see if the project can communicate.

The Macro instructions of HMI Human Machine Interface are based on C language and the system is developed on Linux. There are multi-types of HMI panel, mainly three types, multi touch capacitive hmi panel, plastic shell enconomic resistive hmi touchscreen panel and metal shell wide-temperature resistive touch screen and small home screen to meet different requirement from application scenarios and market needing. There are rich serial port such as rs485, rs232, rs422, ethernet etc to meet the master and slave to use. Mochuan human machine interface manufacturer suppors the size from 4.3inch to 32inch.

There are lots of temperature control in industry automation. It can select temperature module match the main module plc temperature controller, it also use independent temperature controller to control, both of them are to achieve temperature control. If wanna more flexibility in temperature control, maybe indenpendent temperature module is the first choice. Becuase it can operate without main module plc controller. Mochuan independent plc temperature module integrates an excellent self-tuning algorithm, and user can auto-tune with one button according to needs to accurately obtain PID parameters. Through rs485 communication port, communicate with upper computers of various brands, types of plc, touch screen hmi, configuration software and other upper computers to complete morecomplex logic temperature control.

The Fourth Step: Communication Mode Preference is given to the HMI Panel itself with lower computer drive touch screen. Firstly, this is will be more convenient and simple in the definition of the subsequent project address and conversion, becuase if you choose Modbus compatible devices, it is necessary to convert the HMI touch screen monitoring address according to the rules of the definition of different lower computer(PLC) manufacturer, which not only greatly increase the workload of engineers and also easy to covert the wrong. Secondly, needing to draw up in advance, a communication program for the entire project. Do it need the ethernet to communicate with the upper computer, or need two rs485 to be maste or slave station communication, or through one rs485 and one rs232 communication to achieve.